Thermocouple Transmitter
TT 98

 

Thermocouple Transmitter TT 98
 

- Programmable range
- Linearized output standard signal
- 2 Isolated outputs
- Isolation of input, output and power supply
- Cold junction compensation

 

Thermocouple Transmitter TT 98

          The thermocouple’s signal is linearized and cold – junction compensated to provide an isolated and linearized DC. voltage or current output. Typically the TT 98 interfaces with recording, monitoring or controlling instruments.

 

Diagram of Thermocouple Transmitter TT 98
 

Specifications

Thermocouple input

Rangeable within type J 0~800 C

Rangeable within type K 0~1200 C

Rangeable within type R 0~1700 C

Rangeable within type S 0~1700 C

Rangeable within type T -200~200 C

Cold junction compensation

0-50 C

Burn out thermocouple

Upscale drive standard

Linearity

< ± 0.2% of span

Output 1,2

4-20 mA,0-20 mA(max. 1000 ohm load)

0-1 V,0-5 V,1-5 V.(min 1000 ohm load)

Power supply

100 Vac.,110 Vac.,220 Vac.,24 Vdc.

Ambient temperature

0-50 C

Isolations voltage

500Vac(1 min.) between input, output, power supply

Connection

Plug-in 11 pins socket

Mounting

Wall or DIN rail

Dimension

W50 x H70 x D130 mm.

Ordering information

Specify thermocouple type, input range, output1,output2, power supply

Example

TT 98/K/0-400 C/4-20 mA/1-5 Vdc/220 Vac